Deye Grid Tie 50kW Inverter 3phase 400V Three Phase String Inverter SUN-40/45/50K-G04 Growatt Huawei Sungrow Solis
Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs.Setting parameters and FW update remotely, which makes PV plant O&M easier.
Model | SUN-40K-G04 | SUN-45K-G04 | SUN-50K-G04 |
PV String Input Date | |||
Max. PV Input Power(kW) | 52 | 58.5 | 65 |
Max. PV Input Voltage(V) | 1100 | ||
Start-up Voltage(V) | 250 | ||
MPPT voltage range(V) | 200-1000 | ||
Rated PV Input voltage(V) | 600 | ||
Max. Input Short Circuit Current (A) | 60+60+60 | 60+60+60+60 | |
Max. Operating PV Input Current(A) | 40+40+40 | 40+40+40+40 | |
No. of MPPT Trackers/No. of Strings per MPPT Trackers | 3/3+3+3 | 4/3+3+3+3 | |
AC Output Side
|
|||
Rated AC Output Active Power(kW) | 40 | 45 | 50 |
Max. AC Output Apparent Power(kVA) | 44 | 49.5 | 55 |
Rated AC output current (A) | 60.6/58 | 68.2/65.2 | 75.8/72.5 |
Max. AC IOutput Current(A) | 66.7/63.8 | 75/71.7 | 83.3/79.7 |
Rated output voltage/range (V) | 220/380V, 230/400V 0.85Un-1.1Un | ||
Grid Connection Form | 3L/N/PE | ||
Rated Output Grid Frequency/range(Hz) | 50/45-55, 60/55-65 | ||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||
Total Current Harmonic Distortion THDi | <3% | ||
DC Injection Current | <0.5%ln | ||
Efficiency | |||
Max. Efficiency | 98.7% | ||
Euro Efficiency | 98.1% | ||
MPPT Efficiency | >99% | ||
Equipment Protection | |||
DC Polarity Reverse Connection Protection | Yes | ||
AC Output Overcurrent Protection | Yes | ||
AC Output Overvoltage Protection | Yes | ||
AC Output Short Circuit Protection | Yes | ||
Thermal Protection | Yes | ||
DC Terminal Insulation Impedance Monitoring | Yes | ||
DC Component Monitoring | Yes | ||
Ground Fault Current Monitoring | Yes | ||
Power Network Monitoring | Yes | ||
Island Protection Monitoring | Yes | ||
Earth Fault Detection | Yes | ||
Overvoltage Load Drop Protection | Yes | ||
Residual Current (RCD) Detection | Yes | ||
Surge Protection Level | TYPE II(DC),TYPE II(AC) | ||
Interface | |||
Communication Interface | RS485/RS232 | ||
Monitor Mode
|
GPRS/WIFI/Bluetooth/4G/LAN(optional) | ||
General Data | |||
Operating Temperature Range (°C) | -25 to +60ºC, >45ºC Derating | ||
Permissible Ambient Humidity | 0~100% | ||
Permissible Altitude (m) | 4000m | ||
Noise (dB) | ≤ 50 | ||
Ingress Protection(IP) Rating | IP 65 | ||
Inverter Topology | Non-Isolated | ||
Over Voltage Category | OVC II(DC),OVC III(AC) | ||
Cabinet Size (WxHxD mm) | 434×570×243 (Excluding Connectors and Brackets) | ||
Weight [kg] | 37.1 | ||
Warranty [year] | 5 Years | ||
Type Of Cooling | Intelligent Air Cooling | ||
Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
||
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |