SUN-3.6/5/6K-SG03LP1-EU | 3.6-6kW | Single Phase | 2 MPPT | Hybrid Inverter | LV Battery Supported Higher yields / Safe & Reliable / Smart / User-friendly SUN 3.6/6K-SG,hybrid inverter, is suitable for residential and light commercial use, maximizing self-consumption rate of solar energy and increasing your energy impendence. During the day, the PV system generates electricity which will be provided to the loads initially. Then, the excess energy will charge the battery via SUN 3.6/6K-SG. Finally, the stored energy can be released when the loads require it. The battery can also be charged by the diesel generator to ensure uninterrupted supply in the event of grid blackout. It equipped with RS485/CAN port for battery communication Remotely shutdown function Smart Monitoring Platform Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs.Setting parameters and FW update remotely, which makes PV plant O&M easier. Colorful touch LCD, IP65 protection degree AC couple to retrofifit existing solar system Max. 16 pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel Max. charging/discharging current of 135A 6 time periods for battery charging/discharging Support storing energy from diesel generator DOWNLOAD AREA >> Download Datasheet <<>> Download Manual << Technical Specifications SUN-3.6K-SG03LP1-EU SUN-5K-SG03LP1-EU SUN-6K-SG03LP1-EU Feedback |
Model | SUN-3.6K-SG03LP1-EU | SUN-5K-SG03LP1-EU | SUN-6K-SG03LP1-EU |
Battery Input Data | |
Battery Type | Lead-acid or Lithium-ion |
Battery Voltage Range(V) | 40-60 |
Max.Charging Current(A) | 90 | 120 | 135 |
Max.Discharging Current(A) | 90 | 120 | 135 |
Charging Strategy for Li-ion Battery | Self-adaption to BMS |
Number of battery input | 1 |
PV String Input Data | |
Max DC Input Power(W) | 4680 | 6500 | 7800 |
Max DC Input Voltage(V) | 500 |
Start-up Voltage(V) | 125 |
MPPT Voltage Range(V) | 150-425 |
Rated DC Input Voltage(V) | 370 |
Max Input Short-Circuit Current(A) | 17+17 |
Max Operating PV Input Current(A) | 13+13 |
No.of MPP Trackers/No.of String Per MPP Tracker | 2/1+1 |
AC Input/Output Data | |
Rated AC Input/Output Active Power(W) | 3600 | 5000 | 6000 |
Max AC Input/Output Apparent Power (VA) | 3960 | 5500 | 6600 |
Peak Power (off-grid)(W) | 2 times of rated power,10s |
Rated AC Input/Output Current(A) | 16.4/15.7 | 22.7/21.7 | 27.3/26.1 |
Max AC Input/Output Current(A) | 18/17.2 | 25/23.9 | 30/28.7 |
Max Continuous AC Passthrough (grid to load)(A) | 35 | 40 |
Rated Input/Output Voltage/Range(V) | 220V/230 0.85Un-1.1Un |
Grid Connection Form | L+N+PE |
Rated Input/Output Grid Frequency/Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz |
Power Factor Adjustment Range | 0.8 leading-0.8lagging |
Total Current Harmonic Distortion THDi | <3% (of nominal power) |
DC Injection Current | <0.5%ln |
Efficiency | |
Max Efficiency | 97.6% |
Euro Efficiency | 96.5% |
MPPT Efficiency | >99% |
Equipment Protection | |
DC Polarity Reverse Connection Protection | yes |
AC Output Overcurrent Protection | yes |
AC Output Overvoltage Protection | yes |
AC Output Short Circuit Protection | yes |
Thermal Protection | yes |
DC Terminal Insulation Impedance Monitoring | yes |
DC Component Monitoring | yes |
Ground Fault Current Monitoring | yes |
Power Network Monitoring | yes |
Island Protection Monitoring | yes |
Earth Fault Detection | yes |
DC Input Switch | yes |
Overvoltage Load Drop Protection | yes |
Residual Current (RCD) Detection | yes |
Surge Protection Level | TYPE II(DC),TYPE II(AC) |
Interface | |
Communication Interface | WIFI,RS485,CAN |
General Data | |
Operating Temperature Range | -40 to+60ºC,>45ºC Derating |
Permissible Ambient Humidity | 0~100% |
Permissible Altitude | 2000m |
Noise | <30 dB(A) |
Ingress Protection(IP) Rating | IP 65 |
Inverter Topology | Non-Isolated |
Over Voltage Category | OVC II(DC),OVC III(AC) |
Cabinet size(W*H*D)[mm] | 330×580×232 (Excluding Connectors and Brackets) |
Weight[kg] | 25 |
Warranty | 5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
Type Of Cooling | Intelligent air cooling |
Grid Regulation | IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 |
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
Model | SUN-3.6K-SG03LP1-EU | SUN-5K-SG03LP1-EU | SUN-6K-SG03LP1-EU |
Battery Input Data | |
Battery Type | Lead-acid or Lithium-ion |
Battery Voltage Range(V) | 40-60 |
Max.Charging Current(A) | 90 | 120 | 135 |
Max.Discharging Current(A) | 90 | 120 | 135 |
Charging Strategy for Li-ion Battery | Self-adaption to BMS |
Number of battery input | 1 |
PV String Input Data | |
Max DC Input Power(W) | 4680 | 6500 | 7800 |
Max DC Input Voltage(V) | 500 |
Start-up Voltage(V) | 125 |
MPPT Voltage Range(V) | 150-425 |
Rated DC Input Voltage(V) | 370 |
Max Input Short-Circuit Current(A) | 17+17 |
Max Operating PV Input Current(A) | 13+13 |
No.of MPP Trackers/No.of String Per MPP Tracker | 2/1+1 |
AC Input/Output Data | |
Rated AC Input/Output Active Power(W) | 3600 | 5000 | 6000 |
Max AC Input/Output Apparent Power (VA) | 3960 | 5500 | 6600 |
Peak Power (off-grid)(W) | 2 times of rated power,10s |
Rated AC Input/Output Current(A) | 16.4/15.7 | 22.7/21.7 | 27.3/26.1 |
Max AC Input/Output Current(A) | 18/17.2 | 25/23.9 | 30/28.7 |
Max Continuous AC Passthrough (grid to load)(A) | 35 | 40 |
Rated Input/Output Voltage/Range(V) | 220V/230 0.85Un-1.1Un |
Grid Connection Form | L+N+PE |
Rated Input/Output Grid Frequency/Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz |
Power Factor Adjustment Range | 0.8 leading-0.8lagging |
Total Current Harmonic Distortion THDi | <3% (of nominal power) |
DC Injection Current | <0.5%ln |
Efficiency | |
Max Efficiency | 97.6% |
Euro Efficiency | 96.5% |
MPPT Efficiency | >99% |
Equipment Protection | |
DC Polarity Reverse Connection Protection | yes |
AC Output Overcurrent Protection | yes |
AC Output Overvoltage Protection | yes |
AC Output Short Circuit Protection | yes |
Thermal Protection | yes |
DC Terminal Insulation Impedance Monitoring | yes |
DC Component Monitoring | yes |
Ground Fault Current Monitoring | yes |
Power Network Monitoring | yes |
Island Protection Monitoring | yes |
Earth Fault Detection | yes |
DC Input Switch | yes |
Overvoltage Load Drop Protection | yes |
Residual Current (RCD) Detection | yes |
Surge Protection Level | TYPE II(DC),TYPE II(AC) |
Interface | |
Communication Interface | WIFI,RS485,CAN |
General Data | |
Operating Temperature Range | -40 to+60ºC,>45ºC Derating |
Permissible Ambient Humidity | 0~100% |
Permissible Altitude | 2000m |
Noise | <30 dB(A) |
Ingress Protection(IP) Rating | IP 65 |
Inverter Topology | Non-Isolated |
Over Voltage Category | OVC II(DC),OVC III(AC) |
Cabinet size(W*H*D)[mm] | 330×580×232 (Excluding Connectors and Brackets) |
Weight[kg] | 25 |
Warranty | 5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
Type Of Cooling | Intelligent air cooling |
Grid Regulation | IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 |
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |